Generator Interlock Kit Installation

Run your home's essential circuits from a portable generator — safely, legally, and without extension cords through the window.

Portable Generator InterlocksCircuit directory
  1. 1Prevents dangerous backfeed
  2. 2Safe, simple switching
  3. 3Lower cost than a standby generator
  4. 4Choose what you power

A generator interlock lets you power your home's circuits from a portable generator through your electrical panel. A mechanical plate on the panel makes it physically impossible to turn on the main breaker and the generator breaker at the same time, so generator power can never flow back onto the utility lines.

It's the most affordable way to keep the fridge, freezer, well pump, lights and furnace fan running in an outage — something many North Texas homeowners started thinking hard about after the February 2021 winter storm.

What's included in an interlock install

  • An interlock kit listed for your specific panel
  • A dedicated two-pole breaker for the generator feed
  • A weatherproof power inlet box on the outside of the house
  • Wiring between the inlet box and the panel
  • A walkthrough of how to switch over safely

What we do

Prevents dangerous backfeed

Backfeeding the grid can energize lines that utility crews believe are dead. The interlock makes that impossible.

Safe, simple switching

Main off, slide the plate, generator breaker on. Then turn on the circuits you want to run.

Lower cost than a standby generator

Use the portable generator you already own instead of buying and installing a permanent standby unit.

Choose what you power

Because you switch individual breakers, you decide which circuits run — within the capacity of your generator.

Are generator interlock kits legal?

Yes — when the kit is listed for your panel and installed correctly. The National Electrical Code requires transfer equipment that prevents a generator from being connected to the utility at the same time, and a listed interlock does exactly that. Local jurisdictions and utilities can add their own requirements, so the installation should be permitted where required. What's never legal or safe is a “double-male” cord plugged into a wall outlet.

Why generator interlocks are legal and essential for safety →

Interlock, transfer switch or standby generator?

An interlock uses your existing panel and is the lowest-cost option. A manual transfer switch moves selected circuits to a separate sub-panel. A standby generator starts automatically and powers more of the house, at a much higher cost. We'll help you choose based on what you need to keep running.

Sizing your generator

Add up the running watts of what you want to power, plus the starting surge of the largest motor (a well pump or AC compressor). Inlet boxes are typically 30-amp or 50-amp to match your generator's outlet. Always run the generator outdoors, well away from doors and windows — carbon monoxide is the biggest generator danger.

What to Expect

Simple, transparent service from first call to finish.

  1. 1

    Call or Text Anytime

    24/7 scheduling for Azle, Weatherford, Fort Worth and nearby.

  2. 2

    Prompt Arrival

    A licensed & insured electrician arrives in a well-equipped vehicle.

  3. 3

    Up-Front Options & Pricing

    We diagnose the issue and present clear options before any work begins.

  4. 4

    Quality Work, Clean Finish

    Work is completed to code, tested, and the area is left clean.

Portable Generator Interlocks: common questions

Can I run my whole house on a portable generator?

Usually not all at once. Most portable generators can handle essentials — refrigerator, freezer, lights, internet, furnace fan, sometimes a well pump. You choose circuits with your breakers to stay within the generator's capacity.

Do I need a 30-amp or 50-amp inlet box?

It should match your generator's largest outlet. Generators with a 4-prong 30-amp twist-lock outlet use a 30-amp inlet; larger units with a 50-amp outlet use a 50-amp inlet. If you're still shopping for a generator, we'll tell you what works best with your panel.

Is a backfeed cord into an outlet OK in an emergency?

No. A double-male cord can energize the utility lines, endanger line workers, damage your equipment and start fires. An interlock is the safe, code-compliant alternative.